This book presents the nine switch converter based UPQC is simulated using MAT LAB/SIMULINK. It effectively reduces the current and voltage harmonics. The nine-switch converter is more suitable for replacing back- to-back converter in "series-shunt" systems. As a further performance booster, a modified space vector modulation and 120 degree modulation scheme is presented for reducing the overall commutation count by 33%. It is also compensated for voltage sags, total harmonic distortion with proper series and shunt controls. Since the number of switches required is less compared to...
This book presents the nine switch converter based UPQC is simulated using MAT LAB/SIMULINK. It effectively reduces the current and voltage harmonics....
An integral terminal sliding mode control design was proposed to enhance the power quality of wind turbines under unbalanced voltage conditions. The design combines the robustness, fast response, and high quality transient characteristics of the integral terminal sliding mode control with the estimation properties of disturbance observers. It was successfully implemented to both the rotor-side (RSC) and grid side (GSC) converters of a DFIG-based wind turbine. The controller gains were auto tuned using a fuzzy logic approach. Its performance was assessed in the presence of deep voltage sags...
An integral terminal sliding mode control design was proposed to enhance the power quality of wind turbines under unbalanced voltage conditions. The d...
The size and location of DG are the crucial factors in the application of DG for loss minimization. This book presents an algorithm for the identification of bus location using Sensitivity analysis and also an algorithm for the determination of size of the DG using PSO. This methodology is tested on IEEE 15 bus system. By installing DGs at all the potential locations with the determined sizes, the total real power loss of the system has been reduced by 83% and the voltage profile of the system is also improved. The harmonics that are present in the system are reduced by placing capacitors at...
The size and location of DG are the crucial factors in the application of DG for loss minimization. This book presents an algorithm for the identifica...
In this book, the application of the active SFCL into in a power distribution network with DG units is investigated. For the power frequency overvoltage caused by a single-phase grounded fault, the active SFCL can help to reduce the over- voltage's amplitude and avoid damaging the relevant distribution equipment. The active SFCL can as well suppress the short-circuit current induced by a three-phase grounded fault effectively, and the power system's safety and reliability can be improved. Moreover, along with the decrease of the distance between the fault location and the SFCL's installation...
In this book, the application of the active SFCL into in a power distribution network with DG units is investigated. For the power frequency overvolta...