CFD analysis has been done to predict the mass suction into a cylindrical louvered funnel as a function of louvers opening area, diameter of the funnel and the protrusion length of the nozzle into the funnel.Optimum funnel diameter, protrusion length of the nozzle and height of the funnel has been predicted to obtain maximum air suction into the funnel. The entrance length for the sucking funnel has also been predicted as a function of the louvers opening area, diameter of the funnel and the nozzle inlet temperature. Scaled down experimental models have been made to validate the CFD analysis...
CFD analysis has been done to predict the mass suction into a cylindrical louvered funnel as a function of louvers opening area, diameter of the funne...