Neurological diseases in newborns are usually first revealed by seizures, which are characterised by a synchronous discharge of a large number of neurons. Failure to control seizures may lead to brain damage or even death. Neonatal EEG seizures can have signatures in both low frequency (lower than 10 Hz) and high frequency (higher than 70 Hz) areas. The seizures detection techniques proposed in the literature concentrated on using either low frequency or high frequency signatures but not both simultaneously. These methods tend to miss the seizures that reveal themselves only in one of the two...
Neurological diseases in newborns are usually first revealed by seizures, which are characterised by a synchronous discharge of a large number of neur...