Prepared by the Earthquake-Actuated Automatic Gas Shutoff Systems Standards Committee of the Codes and Standards Activities Division of the Structural Engineering Institute of ASCE
This standard provides current minimum functionality requirements for earthquake-actuated automatic gas shutoff devices. These devices contain both a means of sensing seismic activity and a way of shutting off the flow of gas. Applicable to systems carrying natural gas and propane, the devices are used in piping, equipment, and the appliances typically found in structures of three stories or less.
...
Prepared by the Earthquake-Actuated Automatic Gas Shutoff Systems Standards Committee of the Codes and Standards Activities Division of the Structu...
Prepared by the Structural Design of Interlocking Concrete Pavement Committee of the Standards Council of the Transportation & Development Institute of the American Society of Civil Engineers. Cosponsored by the Interlocking Concrete Pavement Institute.
Structural Design of Interlocking Concrete Pavement for Municipal Streets and Roadways, Standard ASCE/T&DI/ICPI 58-16, establishes guidelines for developing appropriate pavement structures for various traffic and subgrade conditions. Interlocking concrete pavers can provide a durable and effective pavement system, but as with...
Prepared by the Structural Design of Interlocking Concrete Pavement Committee of the Standards Council of the Transportation & Development Institut...
Prepared by the Atmospheric Water Management Standards Committee of the Standards Development Council of the Environmental and Water Resources Institute of the American Society of Civil Engineers.Standard Practice for the Design, Conduct, and Evaluation of Operational Precipitation Enhancement Projects describes the application of cloud seeding technologies to facilitate the conversion of atmospheric water vapor into precipitation. By using a variety of meteorological and hydrological observations, water resources engineers can design, implement, and evaluate the effectiveness of...
Prepared by the Atmospheric Water Management Standards Committee of the Standards Development Council of the Environmental and Water Resources Institu...
Prepared by the Management Practice for the Control of Erosion and Sediment (MPCES) Standards Committee of the Standards Development Council of the Environmental and Water Resources Institute of the American Society of Civil Engineers Management Practices for Control of Erosion and Sediment from Construction Activities, Standard ANSI/ASCE/EWRI 66-17, establishes guidelines for controlling accelerated erosion caused by human activities at construction sites. Uncontrolled erosion is costly and accompanied by a host of financial, legal, and environmental problems. This Standard provides tools...
Prepared by the Management Practice for the Control of Erosion and Sediment (MPCES) Standards Committee of the Standards Development Council of the En...
Prepared by the KSTAT Standards Committee of the Standards Development Council of the Environmental and Water Resources Institute of the American Society of Civil EngineersCalculation of the Saturated Hydraulic Conductivity of Fine-Grained Soils is the fourth standard in a series that enhances the probabilistic characterization and understanding of the behavior of a key groundwater parameter, the saturated hydraulic conductivity. Standard ANSI/ASCE/EWRI 65-17 provides guidelines for calculating saturated hydraulic conductivity (Ksat), permeability, and porosity of fine-grained soils. The...
Prepared by the KSTAT Standards Committee of the Standards Development Council of the Environmental and Water Resources Institute of the American Soci...
Prepared by the Schedule Delay Analysis Standard Committee of the Construction Institute of ASCE.Schedule Delay Analysis, Standard ANSI/ASCE/CI 67-17, presents guiding principles that can be used on construction projects to determine the impact of delays. Critical path method (CPM) schedules can be of evidential value to demonstrate causation and liability and to apportion delays when they occur on a project. CPM schedules will influence the quantification of delay and, ultimately, whether a party was damaged by a delay.This standard provides 35 guidelines that allow for segmentation of...
Prepared by the Schedule Delay Analysis Standard Committee of the Construction Institute of ASCE.Schedule Delay Analysis, Standard ANSI/ASCE/CI 67-17,...
Prepared by the Seismic Retrofit of Existing Buildings Standards Committee of the Codes and Standards Activities Division of the Structural Engineering Institute of ASCE.Seismic Evaluation and Retrofit of Existing Buildings, Standard ASCE/SEI 41-17, describes deficiency-based and systematic procedures that use performance-based principles to evaluate and retrofit existing buildings to withstand the effects of earthquakes. The standard presents a three-tiered process for seismic evaluation according to a range of building performance levels by connecting targeted structural performance and the...
Prepared by the Seismic Retrofit of Existing Buildings Standards Committee of the Codes and Standards Activities Division of the Structural Engineerin...
Prepared by the Water Regulatory Standards Committee of the Standards Development Council of the Environmental and Water Resources Institute (EWRI) of the American Society of Civil Engineers Regulated Riparian Model Water Code, ASCE/EWRI 40-18, provides a complete, comprehensive, and well-integrated statutory scheme for creating or refining a regulated riparian system of water law. This system uses a requirement of administrative permits for larger water uses, issued based on the well-established principles of riparian rights, to balance and coordinate those uses in times where demand is...
Prepared by the Water Regulatory Standards Committee of the Standards Development Council of the Environmental and Water Resources Institute (EWRI) of...
Prepared by the Direct Design of Buried Concrete Pipe Box Sections Standards Committee of the Construction Institute of the American Society of Civil Engineers Standard ASCE/CI 27-17 addresses the direct design of precast concrete pipe that will be installed using jacking, a type of trenchless construction. Successful installation of pipe using jacking techniques requires that the engineer design for loading conditions both during and after installation, as well as skillful placement by the installing contractor and precise fabrication of the pipe-all topics covered in this standard. ...
Prepared by the Direct Design of Buried Concrete Pipe Box Sections Standards Committee of the Construction Institute of the American Society of Civil ...
Prepared by the Oxygen Transfer Standards Committee of the Standards Development Council of the Environmental and Water Resources Institute of the American Society of Civil Engineers Standard Guidelines for In-Process Oxygen Transfer Testing provides proven techniques for use by engineers, owners, and manufacturers for measuring oxygen transfer and evaluating the performance of aeration devices under process conditions. Standard ASCE/EWRI 18-18, which was first developed by ASCE in 1996, provides updated information on nonsteady-state, off-gas, and inert gas tracer methods, as well as a...
Prepared by the Oxygen Transfer Standards Committee of the Standards Development Council of the Environmental and Water Resources Institute of the Ame...