• Wyszukiwanie zaawansowane
  • Kategorie
  • Kategorie BISAC
  • Książki na zamówienie
  • Promocje
  • Granty
  • Książka na prezent
  • Opinie
  • Pomoc
  • Załóż konto
  • Zaloguj się

Partial Discharge Detection and Monitoring in Palm Oil » książka

zaloguj się | załóż konto
Logo Krainaksiazek.pl

koszyk

konto

szukaj
topmenu
Księgarnia internetowa
Szukaj
Książki na zamówienie
Promocje
Granty
Książka na prezent
Moje konto
Pomoc
 
 
Wyszukiwanie zaawansowane
Pusty koszyk
Bezpłatna dostawa dla zamówień powyżej 20 złBezpłatna dostawa dla zamówień powyżej 20 zł

Kategorie główne

• Nauka
 [2949524]
• Literatura piękna
 [1817948]

  więcej...
• Turystyka
 [70715]
• Informatyka
 [151291]
• Komiksy
 [35671]
• Encyklopedie
 [23176]
• Dziecięca
 [612440]
• Hobby
 [136066]
• AudioBooki
 [1740]
• Literatura faktu
 [226030]
• Muzyka CD
 [378]
• Słowniki
 [2918]
• Inne
 [445441]
• Kalendarze
 [1181]
• Podręczniki
 [166545]
• Poradniki
 [469898]
• Religia
 [508035]
• Czasopisma
 [502]
• Sport
 [61392]
• Sztuka
 [242759]
• CD, DVD, Video
 [3348]
• Technologie
 [219537]
• Zdrowie
 [98738]
• Książkowe Klimaty
 [124]
• Zabawki
 [2382]
• Puzzle, gry
 [3543]
• Literatura w języku ukraińskim
 [259]
• Art. papiernicze i szkolne
 [7107]
Kategorie szczegółowe BISAC

Partial Discharge Detection and Monitoring in Palm Oil

ISBN-13: 9783659720147 / Angielski / Miękka / 2015 / 116 str.

Ahmed Almawla
Partial Discharge Detection and Monitoring in Palm Oil Almawla, Ahmed 9783659720147 LAP Lambert Academic Publishing - książkaWidoczna okładka, to zdjęcie poglądowe, a rzeczywista szata graficzna może różnić się od prezentowanej.

Partial Discharge Detection and Monitoring in Palm Oil

ISBN-13: 9783659720147 / Angielski / Miękka / 2015 / 116 str.

Ahmed Almawla
cena 223,20
(netto: 212,57 VAT:  5%)

Najniższa cena z 30 dni: 222,68
Termin realizacji zamówienia:
ok. 10-14 dni roboczych.

Darmowa dostawa!

High-voltage transformer is the most critical and expensive component in a power system network in order to ensure the stability of the system. Partial discharge (PD) detection is a technique widely used for high voltage equipment insulation condition monitoring and assessment. PD phenomenon causes gradual deterioration of the insulating materials, sometimes over a period of several years, leading perhaps to eventual failure. Detecting PD in power transformers is vital both in industries and utilities to avoid damage of high-voltage equipment. The objectives for this work are: To detect and analysis the PD activity using acoustic sensor (piezoelectric sensor) and capacitive sensor in natural palm-oil and to compare the sensitivity of the two sensors. The capacitive sensor and PZT sensors were immersed in palm oil tank fitted with two steel electrodes which were connected to range of high voltage (0-15KV) from high voltage source, the detecting signal that gained by the acoustic and electric sensors would pass through high pass filter to eliminate the noise range below 100-KHz then it is connected to the oscilloscope by wiring connections means.

High-voltage transformer is the most critical and expensive component in a power system network in order to ensure the stability of the system. Partial discharge (PD) detection is a technique widely used for high voltage equipment insulation condition monitoring and assessment. PD phenomenon causes gradual deterioration of the insulating materials, sometimes over a period of several years, leading perhaps to eventual failure. Detecting PD in power transformers is vital both in industries and utilities to avoid damage of high-voltage equipment. The objectives for this work are: To detect and analysis the PD activity using acoustic sensor (piezoelectric sensor) and capacitive sensor in natural palm-oil and to compare the sensitivity of the two sensors. The capacitive sensor and PZT sensors were immersed in palm oil tank fitted with two steel electrodes which were connected to range of high voltage (0-15KV) from high voltage source, the detecting signal that gained by the acoustic and electric sensors would pass through high pass filter to eliminate the noise range below 100-KHz then it is connected to the oscilloscope by wiring connections means.

Kategorie:
Nauka, Fizyka
Kategorie BISAC:
Science > Prąd
Wydawca:
LAP Lambert Academic Publishing
Język:
Angielski
ISBN-13:
9783659720147
Rok wydania:
2015
Ilość stron:
116
Waga:
0.18 kg
Wymiary:
22.86 x 15.24 x 0.71
Oprawa:
Miękka
Wolumenów:
01

Ahmed Almawla, Master of Science in Electrical engineering (Electrical Power Engineering) 2012 - 2014, University Technology Malaysia - Johor, Bachelor of Electromechanical Engineering (Electromechanical Systems Engineering) 2007 - 2011, University of Technology- Baghdad-Iraq, Date of birth: December 9th, 1989.



Udostępnij

Facebook - konto krainaksiazek.pl



Opinie o Krainaksiazek.pl na Opineo.pl

Partner Mybenefit

Krainaksiazek.pl w programie rzetelna firma Krainaksiaze.pl - płatności przez paypal

Czytaj nas na:

Facebook - krainaksiazek.pl
  • książki na zamówienie
  • granty
  • książka na prezent
  • kontakt
  • pomoc
  • opinie
  • regulamin
  • polityka prywatności

Zobacz:

  • Księgarnia czeska

  • Wydawnictwo Książkowe Klimaty

1997-2026 DolnySlask.com Agencja Internetowa

© 1997-2022 krainaksiazek.pl
     
KONTAKT | REGULAMIN | POLITYKA PRYWATNOŚCI | USTAWIENIA PRYWATNOŚCI
Zobacz: Księgarnia Czeska | Wydawnictwo Książkowe Klimaty | Mapa strony | Lista autorów
KrainaKsiazek.PL - Księgarnia Internetowa
Polityka prywatnosci - link
Krainaksiazek.pl - płatnośc Przelewy24
Przechowalnia Przechowalnia