• Wyszukiwanie zaawansowane
  • Kategorie
  • Kategorie BISAC
  • Książki na zamówienie
  • Promocje
  • Granty
  • Książka na prezent
  • Opinie
  • Pomoc
  • Załóż konto
  • Zaloguj się

New Geothermal Cooling - Heating System for Buildings » książka

zaloguj się | załóż konto
Logo Krainaksiazek.pl

koszyk

konto

szukaj
topmenu
Księgarnia internetowa
Szukaj
Książki na zamówienie
Promocje
Granty
Książka na prezent
Moje konto
Pomoc
 
 
Wyszukiwanie zaawansowane
Pusty koszyk
Bezpłatna dostawa dla zamówień powyżej 20 złBezpłatna dostawa dla zamówień powyżej 20 zł

Kategorie główne

• Nauka
 [2952079]
• Literatura piękna
 [1850969]

  więcej...
• Turystyka
 [71058]
• Informatyka
 [151066]
• Komiksy
 [35579]
• Encyklopedie
 [23181]
• Dziecięca
 [620496]
• Hobby
 [139036]
• AudioBooki
 [1646]
• Literatura faktu
 [228729]
• Muzyka CD
 [379]
• Słowniki
 [2932]
• Inne
 [445708]
• Kalendarze
 [1409]
• Podręczniki
 [164793]
• Poradniki
 [480107]
• Religia
 [510956]
• Czasopisma
 [511]
• Sport
 [61267]
• Sztuka
 [243299]
• CD, DVD, Video
 [3411]
• Technologie
 [219640]
• Zdrowie
 [100984]
• Książkowe Klimaty
 [124]
• Zabawki
 [2281]
• Puzzle, gry
 [3363]
• Literatura w języku ukraińskim
 [258]
• Art. papiernicze i szkolne
 [8020]
Kategorie szczegółowe BISAC

New Geothermal Cooling - Heating System for Buildings

ISBN-13: 9783659000577 / Angielski / Miękka / 2012 / 104 str.

Pawel Lech
New Geothermal Cooling - Heating System for Buildings Pawel Lech 9783659000577 LAP Lambert Academic Publishing - książkaWidoczna okładka, to zdjęcie poglądowe, a rzeczywista szata graficzna może różnić się od prezentowanej.

New Geothermal Cooling - Heating System for Buildings

ISBN-13: 9783659000577 / Angielski / Miękka / 2012 / 104 str.

Pawel Lech
cena 219,18
(netto: 208,74 VAT:  5%)

Najniższa cena z 30 dni: 218,66
Termin realizacji zamówienia:
ok. 10-14 dni roboczych
Dostawa w 2026 r.

Darmowa dostawa!

Single stage absorption chillers (water/lithium bromide) can operate using low grade heat, thus single stage absorption chillers can operate using low temperature geothermal resources. An EES computer model was written for the single stage absorption chiller based on overall heat transfer coefficients, mass flows, salt balances, energy balances and other assumptions. The single stage model was calibrated with well known and available data from US and Japanese manufacturer. The system was considered to work in hot and humid climate like Abu Dhabi and Shanghai. The results show that in the case when cooling water is 28 C hot the initial and annual total cost is high. However, as cooling water temperature decreases the initial and annual total cost decreases sharply (when cooling water is at 20 C the reduction is around 35% of total annual cost). The results show great influence of cold and hot water on the performance and total annual cost of absorption chiller. A second part of a computer model contains a Total Equivalent Warming Impact (TEWI) analysis. TEWI considers both, the direct refrigerant effect and the primary energy impact on the equivalent carbon dioxide (CO2) emission."

Single stage absorption chillers (water/lithium bromide) can operate using low grade heat, thus single stage absorption chillers can operate using low temperature geothermal resources. An EES computer model was written for the single stage absorption chiller based on overall heat transfer coefficients, mass flows, salt balances, energy balances and other assumptions. The single stage model was calibrated with well known and available data from US and Japanese manufacturer. The system was considered to work in hot and humid climate like Abu Dhabi and Shanghai. The results show that in the case when cooling water is 28°C hot the initial and annual total cost is high. However, as cooling water temperature decreases the initial and annual total cost decreases sharply (when cooling water is at 20°C the reduction is around 35% of total annual cost). The results show great influence of cold and hot water on the performance and total annual cost of absorption chiller. A second part of a computer model contains a Total Equivalent Warming Impact (TEWI) analysis. TEWI considers both, the direct refrigerant effect and the primary energy impact on the equivalent carbon dioxide (CO2) emission.

Kategorie:
Technologie
Kategorie BISAC:
Technology & Engineering > Electrical
Wydawca:
LAP Lambert Academic Publishing
Język:
Angielski
ISBN-13:
9783659000577
Rok wydania:
2012
Ilość stron:
104
Waga:
0.16 kg
Wymiary:
22.86 x 15.24 x 0.64
Oprawa:
Miękka
Wolumenów:
01

Life is just a sum of shorter and shorter breaths, which sometimes, if faith and God allows, are interrupted by reckless energy dissipation well known as luck, love, happiness and many others.Once our circuit has gathered enough (too much) used-processed memories which are nothing else than memory of internal and vital energy which we all had.



Udostępnij

Facebook - konto krainaksiazek.pl



Opinie o Krainaksiazek.pl na Opineo.pl

Partner Mybenefit

Krainaksiazek.pl w programie rzetelna firma Krainaksiaze.pl - płatności przez paypal

Czytaj nas na:

Facebook - krainaksiazek.pl
  • książki na zamówienie
  • granty
  • książka na prezent
  • kontakt
  • pomoc
  • opinie
  • regulamin
  • polityka prywatności

Zobacz:

  • Księgarnia czeska

  • Wydawnictwo Książkowe Klimaty

1997-2025 DolnySlask.com Agencja Internetowa

© 1997-2022 krainaksiazek.pl
     
KONTAKT | REGULAMIN | POLITYKA PRYWATNOŚCI | USTAWIENIA PRYWATNOŚCI
Zobacz: Księgarnia Czeska | Wydawnictwo Książkowe Klimaty | Mapa strony | Lista autorów
KrainaKsiazek.PL - Księgarnia Internetowa
Polityka prywatnosci - link
Krainaksiazek.pl - płatnośc Przelewy24
Przechowalnia Przechowalnia